Introduction
Configuring dozens of tags by hand — one address at a time, one index at a time — is where time is lost and numbers get mistyped. For that, several numeric properties of PascalSCADA components accept, in the Object Inspector, an expression instead of a number: you type memaddress+2, Tag*4 or selindex*30 and the IDE computes the value. Combined with Lazarus’ multiple selection, this configures a hundred components in one keystroke.
It is a design-time feature: the expression is evaluated when you press Enter and what gets stored in the .lfm is the resulting number. Nothing changes at run time — for values computed at run time, use TNumericExprTag.
The feature was announced in the post Expressions on all properties of base tags; the video below shows it in use:
How to type it
In the Object Inspector, in the property field, type the expression and press Enter. Two forms:
| You type | What happens |
|---|---|
100 |
A normal value. |
10*8+3 |
Absolute expression: the property receives the result (83). |
+2, -10, *2, /2 |
Relative expression: it starts with an operator, and the property’s current value is put in front. +2 on a MemAddress = 40 gives 42; *2 gives 80. |
memaddress+2 |
Expression with variables (each property’s list is below). |
The result is always an integer: divisions are truncated (7/2 → 3). With a multiple selection the expression is evaluated once for each selected component, with that component’s variables — which is what lets memaddress+100 shift ten tags at once, each from its own address.
Syntax
The evaluator is Free Pascal’s TFPExpressionParser, with the math functions enabled:
- operators:
+ - * / ^(power),mod, parentheses; - comparison and logic:
= <> < > <= >=,and,or,not; if(condition, ifTrue, ifFalse)andcase(selector, v1, r1, v2, r2, …, default);- functions:
abs,sqr,sqrt,round,trunc,int,frac,exp,ln,log,sin,cos,arctan,pi; - variable names are case-insensitive (
MemAddressandmemaddressare the same).
There is no div: use trunc(a/b) (or just a/b, already truncated when stored).
Where it works and which variables exist
Tag addressing properties — on TPLCTagNumber, TPLCBlock, TPLCStruct and TPLCString, the properties PLCRack, PLCSlot, PLCStation, MemFile_DB, MemAddress, MemSubElement, MemReadFunction, MemWriteFunction and, on blocks and structures, Size. Available variables: the other properties of that list (plcrack, plcslot, plcstation, memfile_db, memaddress, memsubelement, memreadfunction, memwritefunction) and Tag (the component’s Tag property, a free integer). The property being edited is left out, to avoid a circular reference.
Index — on TPLCBlockElement, TPLCStructItem and TPLCStructString. Variable: Tag. (On TPLCBlockElement the field’s drop-down also offers the block’s valid indexes.)
Position and size of any control — Left, Top, Width and Height of every TControl on the form, not just PascalSCADA controls. Variables: left, top, width, height, tag and selindex.
Tag — the Tag property of any TComponent. Variables: the same position ones (left… when it is a control) and selindex.
selindex is the component’s index within the current selection (0 for the first selected, 1 for the second…). It is the variable that turns a multiple selection into automatic numbering.
Recipes
All start from a multiple selection on the form or datamodule (Shift+click, or dragging a frame).
Number the elements of a block. Select the 16 hand-made TPLCBlockElements in the desired order:
- in
Tag, typeselindex→ each gets 0, 1, 2… 15; - in
Index, typeTag→Index= 0, 1, 2… 15.
The same goes for TPLCStructItem with regular offsets: Index = Tag*2 for INT fields, Tag*4 for REAL.
Consecutive tags. Ten TPLCTagNumbers that must point to D100, D101, … D109: select the ten, Tag = selindex, then MemAddress = 100+Tag.
Shift a set of addresses. The DB moved and every tag must advance 50 bytes: select them and type +50 in MemAddress. Changed DB: MemFile_DB = 12 on the whole selection.
Copied struct. You copied the items of a TPLCStruct to represent a second device whose structure sits 64 bytes further: select the copied items and type +64 in Index.
Write function consistent with the read one. On Modbus tags, MemWriteFunction = if(memreadfunction=1, 15, 16) picks the right block write function for each tag, according to whether it reads coils or registers.
Align controls. Select ten THMILabels and type selindex*24+8 in Top and 16 in Left: a column with a 24 px pitch. A 4×4 button grid: Left = (selindex mod 4)*90, Top = trunc(selindex/4)*40.
Stack controls of different sizes. Top = selindex*(height+4) only works when all have the same height; for different heights, align in two passes or use Lazarus’ Anchor Editor.
Limits
- Object Inspector only: not from code, nor in properties edited in other dialogs (Tag Builder, collection editors).
- Variables read the current value of the other selected components; an expression depending on a property you are still going to change must be typed after it.
- Only the integer properties listed above.
RefreshTime,MinValue, the zones’Value1and others do not accept expressions (for now — the list is insrc/scada_dsng/scadareg.pasandsrc/hmi/hmiregister.pas, and extending it means registering one moreTTagAddressPropertyEditor). - A syntax error is reported by the IDE and the property is left unchanged.
Related examples
examples/laz_isotcp_demonstrationandexamples/laz_isotcp_hourmeter— dozens ofTPLCBlockElements andTTagBits with sequential indexes, the typical scenario of the recipes above.examples/TagTypes— block elements and structure items with computed offsets.